產(chǎn)品簡介
模擬量輸入BECKHOFF模塊KL3314
4 通道模擬量輸入端子模塊, 0/4…20 mA
上海勇控自動化提供。庫存充足,*。
4 通道模擬量輸入端子模塊, 0/4…20 mA
上海勇控自動化提供。庫存充足,*。
上海勇控自動化設(shè)備有限公司 |
—— 銷售熱線 ——
15801922503 |
模擬量輸入BECKHOFF模塊KL3314
模擬量輸入BECKHOFF模塊KL3314
KL3314 模擬量輸入端子模塊可以直接連接四個熱電偶??偩€端子模塊電路可采用 2 線制連接技術(shù)來連接熱電偶傳感器。整個溫度范圍(可任意選定)的線性度由一個微處理器來實現(xiàn)。故障 LED 指示斷線狀態(tài)。冷端補償由總線端子模塊內(nèi)的內(nèi)部溫度測量線路來完成。KL3314 也可用于測量 mV 信號。
技術(shù)參數(shù) | KL3314 |
---|---|
輸入點數(shù) | 4 |
電源 | 通過 K-bus 供電 |
熱電偶傳感器類型 | J、K、L、B、E、N、R、S、T、U 型(默認(rèn)設(shè)置:K 型),mV 信號測量 |
連接方式 | 2 線制 |
溫度范圍 | 取決于每種傳感器的測量范圍 (默認(rèn)設(shè)置:K 型: -100…+1,370 °C) |
分辨率 | 0.1 °C/數(shù)位 |
轉(zhuǎn)換時間 | ~ 250 ms |
電源模塊BECKHOFF KL9100
:文工
:
:zhiyong542701
:
BC9020 | Bus Terminal | “Economy plus” Bus Terminal Controller with integrated IEC 61131-3 PLC, 128 kbytes program memory, Ethernet TCP/IP interface; Ethernet protocols TwinCAT ADS, Modbus TCP |
BC9050 | Bus Terminal | “Compact“ Bus Terminal Controller with integrated IEC 61131-3 PLC, 48 kbytes program memory, Ethernet TCP/IP interface; Ethernet protocols TwinCAT ADS, Modbus TCP |
BC9100 | Bus Terminal | Bus Terminal Controller with integrated IEC 61131-3 PLC, 64 kbytes program memory, Ethernet TCP/IP interface and integrated 2-channel switch; Ethernet protocols TwinCAT ADS, Modbus TCP |
BC9120 | Bus Terminal | “Economy plus” Bus Terminal Controller with integrated IEC 61131-3 PLC, 128 kbytes program memory, Ethernet TCP/IP interface and integrated 2-channel switch; Ethernet protocols TwinCAT ADS, Modbus TCP |
BC9191 | Bus Terminal | Bus Terminal Controller with integrated IEC 61131-3 PLC, Ethernet TCP/IP interface and integrated 2-channel switch – Program memory: 48 kbytes – Supply voltage: 230 V AC – Ethernet protocols: TwinCAT ADS, Modbus TCP – Sub bus system: 1 connection to EnOcean KL6583 – K-bus interface – on board I/Os: – 3 digital inputs – 1 analog input PT/NI1000 – 1 analog input, resistance measurement for set value specification (0…10 kΩ) – 3 analog inputs 0...10 V – 1 digital output for LED, 10 mA – 1 digital relay output 230 V AC, 10 A – 3 digital relay outputs 230 V AC, 1 A – 2 digital triac outputs 230 V AC, 1 A – 2 analog outputs 0…10 V |
BC9191-0100 | Bus Terminal | Bus Terminal Controller with integrated IEC 61131-3 PLC, Ethernet TCP/IP interface and integrated 2-channel switch – Program memory: 128 kbytes – Supply voltage: 230 V AC – Ethernet protocols: TwinCAT ADS, Modbus TCP – Sub bus system: 1 x RS485 – K-bus interface – on board I/Os: – 3 digital inputs – 1 analog input 1 x Pt/NI1000 – 1 analog input, resistance measurement for set value specification (0…10 kΩ) – 3 analog inputs 0...10 V – 1 digital output for LED, 10 mA – 1 digital relay output 230 V AC, 10 A – 3 digital relay outputs 230 V AC, 1 A – 2 digital triac outputs 230 V AC, 1 A – 2 analog outputs 0…10 V |