五月婷网站,av先锋丝袜天堂,看全色黄大色大片免费久久怂,中国人免费观看的视频在线,亚洲国产日本,毛片96视频免费观看

產(chǎn)品展廳收藏該商鋪

您好 登錄 注冊(cè)

當(dāng)前位置:
美國(guó)布魯克海文儀器公司>資料下載>Nanobrook Omni測(cè)量應(yīng)用案例-19

資料下載

Nanobrook Omni測(cè)量應(yīng)用案例-19

閱讀:319          發(fā)布時(shí)間:2018-6-19
提 供 商 美國(guó)布魯克海文儀器公司 資料大小 1.8MB
資料圖片 下載次數(shù) 103次
資料類(lèi)型 PDF 文件 瀏覽次數(shù) 319次
免費(fèi)下載 點(diǎn)擊下載    

文獻(xiàn)名:Introducing a nested phase change agent with an acoustic response that depends on electric field: A candidate for myocardial perfusion imaging and drug delivery 

 

作者Michael Cimorellia, Brett Angelb, Aaron Fafarmana, Andrew Kohutb, Benjamin Andriena, Kyle Barretta, StevenWrenna 

a    Chemical and Biological Engineering, Drexel University, Philadelphia, PA, United States

b    Cardiology, Drexel University College of Medicine, Philadelphia, PA, United States

 

摘要:We present a voltage-sensitive phase change agent comprising an aqueous emulsion of surfactant-coated liquid perfluorocarbon droplets nested within a negatively charged phospholipid bilayer. The sensitivity to voltage allows, via exposure to an electric field, acoustic activation of the perfluorocarbon droplets at an ultrasound intensity that is otherwise insufficient to cause activation. The result is a phase change agent for which activation depends not on ultrasound intensity but rather on the presence of an electric field. Accordingly, we offer the first enhanced ultrasound contrast agent (Electrast) that takes advantage of the electrical activity of the heart and leads to selective activation at a fixed mechanical index (MI). Being voltage-sensitive, Electrast activates selectively in the coronary circulation, giving enhanced ultrasound contrast within the myocardium while leaving other regions largely unenhanced. Specifically, in a closed chest swine study, the contrast enhancement between the myocardium and the left ventricle increased by 36.4?dB ±0.2 upon injection of a charged, nested PCA formulation at a fixed MI of 0.9 (GE Vivid i). Similar enhancement was observed in rats, and the contrast-to-tissue ratio increased by nearly 10?dB at an MI of 0.28 upon exposure to an electric field of 1?V/cm in a tissue-mimicking phantom. Additionally, ultrasound-induced leakage of calcein, a water-soluble fluorescent dye, from a nested, charged PCA formulation more than doubled at a peak negative pressure of 0.5?MPa upon exposure to an electric field of 0.25?V/cm. These results suggest that Electrast, a voltage-sensitive phase change agent, is a candidate for myocardial perfusion imaging using ultrasound.

收藏該商鋪

請(qǐng) 登錄 后再收藏

提示

您的留言已提交成功!我們將在第一時(shí)間回復(fù)您~

對(duì)比框

產(chǎn)品對(duì)比 產(chǎn)品對(duì)比 聯(lián)系電話(huà) 二維碼 意見(jiàn)反饋 在線(xiàn)交流

掃一掃訪(fǎng)問(wèn)手機(jī)商鋪
010-62081908
在線(xiàn)留言