產(chǎn)地類別 | 進(jìn)口 |
---|
西門子PLC可編程控制器,西門子PLC200/300/400/1200,西門子變頻器,電源模塊軟啟動(dòng)器,西門子低壓產(chǎn)品,西門子數(shù)控伺服,西門子傳動(dòng),西門子工控系列模塊,CPU.等系列西門子銷售與維修。
![]() |
參考價(jià) | 面議 |
更新時(shí)間:2017-11-16 16:06:06瀏覽次數(shù):372
聯(lián)系我們時(shí)請(qǐng)說明是化工儀器網(wǎng)上看到的信息,謝謝!
西門子6ES7531-7NF10-OABO
模擬量輸出模塊可以將 16 位數(shù)字值轉(zhuǎn)換為電流或電壓并輸出到過程。例如,它們適合控制比例閥或小型伺服驅(qū)動(dòng)器。
提供有以下模擬量輸出模塊:
上海晉營自動(dòng)化科技有限公司銷售西門子千萬余產(chǎn)品 盡新老顧您來詢價(jià)訂貨采購,歡迎您來晉營公司,謝謝您的光臨!您的合作是我zui大的榮幸!Thank you very much!
上海晉營自動(dòng)化科技有限公司
:邵澤春
電 話:(同號(hào))
郵 箱:3117125529
: 3117125529
西門子6ES7531-7NF10-OABO
|
設(shè)計(jì)
功能
技術(shù)規(guī)范
模擬量輸入模塊可以記錄壓力或溫度等過程信號(hào),并以數(shù)字形式(16 位形式)將它們傳送給控制器。這些模塊適用于測(cè)量電流(2 線制和 4 線制傳感器)、電壓和電阻,并適合連接電阻溫度計(jì)和熱電偶(測(cè)量類型取決于模塊)。
提供有以下模擬量輸入模塊:
含在供貨范圍之內(nèi):
Article number | 6ES7531-7QD00-0AB0 | 6ES7531-7KF00-0AB0 | 6ES7531-7NF10-0AB0 | 6ES7531-7NF00-0AB0 | |
---|---|---|---|---|---|
| S7-1500, AI 4XU/I/RTD/TC ST | S7-1500, AI 8XU/I/RTD/TC ST | S7-1500, AI 8XU/I HS | S7-1500, AI 8XU/I HF | |
General information |
|
|
|
| |
Product type designation | AI 4xU/I/RTD/TC ST | AI 8xU/I/RTD/TC ST | AI 8xU/I HS | AI 8xU/I HF | |
HW functional status | FS01 | FS01 | FS01 | FS01 | |
Firmware version | V1.0.0 | V2.0.0 | V2.1.0 | V1.1.0 | |
| Yes | Yes | Yes | Yes | |
Product function |
|
|
|
| |
| Yes; I&M0 to I&M3 | Yes; I&M0 to I&M3 | Yes; I&M0 to I&M3 | Yes; I&M0 to I&M3 | |
| No | No | No | No | |
| No | No | No | Yes | |
| No | No | No | Yes | |
Engineering with |
|
|
|
| |
| V13 / V13.0.2 | V12 / V12 | V14 / - | V14 / - | |
| V5.5 SP3 / - | V5.5 SP3 / - | V5.5 SP3 / - | V5.5 SP3 / - | |
| V1.0 / V5.1 | V1.0 / V5.1 | V1.0 / V5.1 | V1.0 / V5.1 | |
| V2.3 / - | V2.3 / - | V2.3 / - | V2.3 / - | |
Operating mode |
|
|
|
| |
| No | No | Yes | No | |
| Yes | Yes | Yes | Yes | |
CiR – Configuration in RUN |
|
|
|
| |
Reparameterization possible in RUN | Yes | Yes | Yes | Yes | |
Calibration possible in RUN | Yes | Yes | Yes | Yes | |
Supply voltage |
|
|
|
| |
Rated value (DC) | 24 V | 24 V | 24 V | 24 V | |
permissible range, lower limit (DC) | 20.4 V | 20.4 V | 20.4 V | 20.4 V | |
permissible range, upper limit (DC) | 28.8 V | 28.8 V | 28.8 V | 28.8 V | |
Reverse polarity protection | Yes | Yes | Yes | Yes | |
Input current |
|
|
|
| |
Current consumption, max. | 140 mA; with 24 V DC supply | 240 mA; with 24 V DC supply | 240 mA; with 24 V DC supply | 50 mA; with 24 V DC supply | |
Encoder supply |
|
|
|
| |
24 V encoder supply |
|
|
|
| |
| Yes | Yes | Yes |
| |
| 20 mA; Max. 47 mA per channel for a duration < 10 s | 20 mA; Max. 47 mA per channel for a duration < 10 s | 20 mA; Max. 47 mA per channel for a duration < 10 s |
| |
Power |
|
|
|
| |
Power available from the backplane bus | 0.7 W | 0.7 W | 1.15 W | 0.85 W | |
Power loss |
|
|
|
| |
Power loss, typ. | 2.3 W | 2.7 W | 3.4 W | 1.9 W | |
Analog inputs |
|
|
|
| |
Number of analog inputs | 4 | 8 | 8 | 8 | |
| 4 | 8 | 8 | 8 | |
| 4 | 8 | 8 | 8 | |
| 2 | 4 |
|
| |
| 4 | 8 |
|
| |
permissible input voltage for voltage input (destruction limit), max. | 28.8 V | 28.8 V | 28.8 V | 28.8 V | |
permissible input current for current input (destruction limit), max. | 40 mA | 40 mA | 40 mA | 40 mA | |
Technical unit for temperature measurement adjustable | Yes; °C/°F/K | Yes; °C/°F/K |
|
| |
Analog input with oversampling | No |
|
|
| |
Standardization of measured values | No |
|
|
| |
Input ranges (rated values), voltages |
|
|
|
| |
| No | No | No | No | |
| No | No | No | No | |
| Yes | Yes | Yes | Yes | |
| 100 k? | 100 k? | 50 k? | 100 k? | |
| Yes | Yes |
|
| |
| 10 M? | 10 M? |
|
| |
| Yes | Yes | Yes | Yes | |
| 100 k? | 100 k? | 100 k? | 100 k? | |
| Yes | Yes | No | Yes | |
| 10 M? | 10 M? |
| 100 k? | |
| No | No | No | No | |
| Yes | Yes | No | No | |
| 10 M? | 10 M? |
|
| |
| Yes | Yes | Yes | Yes | |
| 100 k? | 100 k? | 50 k? | 100 k? | |
| Yes | Yes | No | No | |
| 10 M? | 10 M? |
|
| |
| Yes | Yes | No | No | |
| 10 M? | 10 M? |
|
| |
| Yes | Yes | No | No | |
| 10 M? | 10 M? |
|
| |
Input ranges (rated values), currents |
|
|
|
| |
| Yes | Yes | Yes | Yes | |
| 25 ?; Plus approx. 42 ohms for overvoltage protection by PTC | 25 ?; Plus approx. 42 ohms for overvoltage protection by PTC | 41 ?; Plus approx. 42 ohms for overvoltage protection by PTC | 25 ?; Plus approx. 42 ohms for overvoltage protection by PTC | |
| Yes | Yes | Yes | Yes | |
| 25 ?; Plus approx. 42 ohms for overvoltage protection by PTC | 25 ?; Plus approx. 42 ohms for overvoltage protection by PTC | 41 ?; Plus approx. 42 ohms for overvoltage protection by PTC | 25 ?; Plus approx. 42 ohms for overvoltage protection by PTC | |
| Yes | Yes | Yes | Yes | |
| 25 ?; Plus approx. 42 ohms for overvoltage protection by PTC | 25 ?; Plus approx. 42 ohms for overvoltage protection by PTC | 41 ?; Plus approx. 42 ohms for overvoltage protection by PTC | 25 ?; Plus approx. 42 ohms for overvoltage protection by PTC | |
Input ranges (rated values), thermocouples |
|
|
|
| |
| Yes | Yes | No | No | |
| 10 M? | 10 M? |
|
| |
| No | No | No | No | |
| Yes | Yes | No | No | |
| 10 M? | 10 M? |
|
| |
| Yes | Yes | No | No | |
| 10 M? | 10 M? |
|
| |
| Yes | Yes | No | No | |
| 10 M? | 10 M? |
|
| |
| No | No | No | No | |
| Yes | Yes | No | No | |
| 10 M? | 10 M? |
|
| |
| Yes | Yes | No | No | |
| 10 M? | 10 M? |
|
| |
| Yes | Yes | No | No | |
| 10 M? | 10 M? |
|
| |
| Yes | Yes | No | No | |
| 10 M? | 10 M? |
|
| |
| No |
|
|
| |
| No | No | No | No | |
Input ranges (rated values), resistance thermometer |
|
|
|
| |
| No | No | No | No | |
| No | No | No | No | |
| No | No | No | No | |
| No | No | No | No | |
| No | No | No | No | |
| No | No | No | No | |
| No | No | No | No | |
| No | No | No | No | |
| Yes; Standard/climate | Yes; Standard/climate | No | No | |
| 10 M? | 10 M? |
|
| |
| No | No | No | No | |
| Yes; Standard/climate | Yes; Standard/climate | No | No | |
| 10 M? | 10 M? |
|
| |
| No | No | No | No | |
| Yes; Standard/climate | Yes; Standard/climate | No | No | |
| 10 M? | 10 M? |
|
| |
| No | No | No | No | |
| No | No | No | No | |
| No |
| No | No | |
| No | No | No | No | |
| No | No | No | No | |
| No | No | No | No | |
| No | No | No | No | |
| No | No | No | No | |
| No | No | No | No | |
| No | No | No | No | |
| Yes; Standard/climate | Yes; Standard/climate | No | No | |
| 10 M? | 10 M? |
|
| |
| No | No | No | No | |
| Yes; Standard/climate | Yes; Standard/climate | No | No | |
| 10 M? | 10 M? |
|
| |
| No | No | No | No | |
| Yes; Standard/climate | Yes; Standard/climate | No | No | |
| 10 M? | 10 M? |
|
| |
| No | No | No | No | |
| Yes; Standard/climate | Yes; Standard/climate | No | No | |
| 10 M? | 10 M? |
|
| |
| No | No | No | No | |
Input ranges (rated values), resistors |
|
|
|
| |
| Yes | Yes | No | No | |
| 10 M? | 10 M? |
|
| |
| Yes | Yes | No | No | |
| 10 M? | 10 M? |
|
| |
| Yes | Yes | No | No | |
| 10 M? | 10 M? |
|
| |
| No | No | No | No | |
| Yes | Yes | No | No | |
| 10 M? | 10 M? |
|
| |
| Yes | Yes | No | No | |
| 10 M? | 10 M? |
|
| |
Thermocouple (TC) |
|
|
|
| |
Temperature compensation |
|
|
|
| |
| Yes | Yes |
|
| |
| Yes | Yes |
|
| |
| Yes | Yes |
|
| |
| Yes; fixed value can be set | Yes; fixed value can be set |
|
| |
| No | Yes |
|
| |
Cable length |
|
|
|
| |
| 800 m; for U/I, 200 m for R/RTD, 50 m for TC | 800 m; for U/I, 200 m for R/RTD, 50 m for TC | 800 m | 800 m | |
Analog value generation for the inputs |
|
|
|
| |
Integration and conversion time/resolution per channel |
|
|
|
| |
| 16 bit | 16 bit | 16 bit | 24 bit; When using the function "Scaling of the measured values" or "Measuring range adaptation" (32-bit REAL format); 16 bit when using the S7 format (16-bit INTEGER) | |
| Yes | Yes |
| Yes | |
| 2,5 / 16,67 / 20 / 100 ms | 2,5 / 16,67 / 20 / 100 ms |
| Fast mode: 2.5 / 16.67 / 20 / 100 ms, standard mode: 7.5 / 50 / 60 / 300 ms | |
| 9 / 23 / 27 / 107 ms | 9 / 23 / 27 / 107 ms |
| Fast mode: 4 / 18 / 22 / 102 ms; Standard mode: 9 / 52 / 62 / 302 ms | |
| 9 ms (to be considered in R/RTD/TC measurement) | 9 ms (to be considered in R/RTD/TC measurement) |
|
| |
| 150 ohm, 300 ohm, 600 ohm, Pt100, Pt200, Ni100: 2 ms, 6000 ohm, Pt500, Pt1000, Ni1000, LG-Ni1000, PTC: 4 ms | 150 ohm, 300 ohm, 600 ohm, Pt100, Pt200, Ni100: 2 ms, 6000 ohm, Pt500, Pt1000, Ni1000, LG-Ni1000, PTC: 4 ms |
|
| |
| 400 / 60 / 50 / 10 | 400 / 60 / 50 / 10 Hz |
| 400 / 60 / 50 / 10 Hz | |
|
|
|
| Corresponds to the channel with the highest basic conversion time | |
|
|
| 62.5 µs; independent of number of activated channels |
| |
| Basic conversion time of the slowest channel | Basic conversion time of the slowest channel |
|
| |
Smoothing of measured values |
|
|
|
| |
| Yes | Yes | Yes | Yes | |
| Yes | Yes | Yes | Yes | |
| Yes | Yes | Yes | Yes | |
| Yes | Yes | Yes | Yes | |
| Yes | Yes | Yes | Yes | |
Encoder |
|
|
|
| |
Connection of signal encoders |
|
|
|
| |
| Yes | Yes | Yes | Yes | |
| Yes | Yes | Yes | Yes; with external transmitter supply | |
| 820 ? | 820 ? | 820 ? |
| |
| Yes | Yes | Yes | Yes | |
| Yes; Only for PTC | Yes; Only for PTC | No | No | |
| Yes; All measuring ranges except PTC; internal compensation of the cable resistances | Yes; All measuring ranges except PTC; internal compensation of the cable resistances | No | No | |
| Yes; All measuring ranges except PTC | Yes; All measuring ranges except PTC | No | No | |
Errors/accuracies |
|
|
|
| |
Linearity error (relative to input range), (+/-) | 0.02 % | 0.02 % | 0.02 % | 0.02 % | |
Temperature error (relative to input range), (+/-) | 0.005 %/K; With TC type T 0.02 ± % / K | 0.005 %/K; With TC type T 0.02 ± % / K | 0.005 %/K | 0.005 %/K | |
Crosstalk between the inputs, max. | -80 dB | -80 dB | -60 dB | -80 dB | |
Repeat accuracy in steady state at 25 °C (relative to input range), (+/-) | 0.02 % | 0.02 % | 0.02 % | 0.02 % | |
Temperature error of internal compensation | ±6 °C | ±6 °C |
|
| |
Operational error limit in overall temperature range |
|
|
|
| |
| 0.3 % | 0.3 % | 0.3 % | 0.1 % | |
| 0.3 % | 0.3 % | 0.3 % | 0.1 % | |
| 0.3 % | 0.3 % |
|
| |
| 0.3 %; Ptxxx standard: ±1.5 K, Ptxxx climate: ±0.5 K, Nixxx standard: ±0.5 K, Nixxx climate: ±0.3 K | Ptxxx standard: ±1.5 K, Ptxxx climate: ±0.5 K, Nixxx standard: ±0.5 K, Nixxx climate: ±0.3 K |
|
| |
| 0.3 %; Type B: > 600 °C ±4.6 K, type E: > -200 °C ±1.5 K, type J: > -210 °C ±1.9 K, type K: > -200 °C ±2.4 K, type N: > -200 °C ±2.9 K, type R: > 0 °C ±4.7 K, type S: > 0 °C ±4.6 K, type T: > -200 °C ±2.4 K | Type B: > 600 °C ±4.6 K, type E: > -200 °C ±1.5 K, type J: > -210 °C ±1.9 K, type K: > -200 °C ±2.4 K, type N: > -200 °C ±2.9 K, type R: > 0 °C ±4.7 K, type S: > 0 °C ±4.6 K, type T: > -200 °C ±2.4 K |
|
| |
Basic error limit (operational limit at 25 °C) |
|
|
|
| |
| 0.1 % | 0.1 % | 0.2 % | 0.05 % | |
| 0.1 % | 0.1 % | 0.2 % | 0.05 % | |
| 0.1 % | 0.1 % |
|
| |
| 0.1 %; Ptxxx standard: ±0.7 K, Ptxxx climate: ±0.2 K, Nixxx standard: ±0.3 K, Nixxx climate: ±0.15 K | Ptxxx standard: ±0.7 K, Ptxxx climate: ±0.2 K, Nixxx standard: ±0.3 K, Nixxx climate: ±0.15 K |
|
| |
| 0.1 %; Type B: > 600 °C ±1.7 K, type E: > -200 °C ±0.7 K, type J: > -210 °C ±0.8 K, type K: > -200 °C ±1.2 K, type N: > -200 °C ±1.2 K, type R: > 0 °C ±1.9 K, type S: > 0 °C ±1.9 K, type T: > -200 °C ±0.8 K | Type B: > 600 °C ±1.7 K, type E: > -200 °C ±0.7 K, type J: > -210 °C ±0.8 K, type K: > -200 °C ±1.2 K, type N: > -200 °C ±1.2 K, type R: > 0 °C ±1.9 K, type S: > 0 °C ±1.9 K, type T: > -200 °C ±0.8 K |
|
| |
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency |
|
|
|
| |
| 40 dB | 40 dB |
| 80 dB; in the Standard operating mode, 40 dB in the Fast operating mode | |
| 10 V | 10 V | 10 V | 60 V DC/30 V AC | |
| 60 dB | 60 dB | 50 dB at 400 Hz; 60 dB at 60 / 50 / 10 Hz | 80 dB | |
Isochronous mode |
|
|
|
| |
Isochronous operation (application synchronized up to terminal) | No | No | Yes | No | |
Filtering and processing time (TCI), min. |
|
| 80 µs |
| |
Bus cycle time (TDP), min. |
|
| 250 µs |
| |
Interrupts/diagnostics/status information |
|
|
|
| |
Diagnostics function | Yes | Yes | Yes | Yes | |
Alarms |
|
|
|
| |
| Yes | Yes | Yes | Yes | |
| Yes; two upper and two lower limit values in each case | Yes; two upper and two lower limit values in each case | Yes; two upper and two lower limit values in each case | Yes; two upper and two lower limit values in each case | |
Diagnostic messages |
|
|
|
| |
| Yes | Yes | Yes | Yes | |
| Yes; Only for 1 to 5 V, 4 to 20 mA, TC, R, and RTD | Yes; Only for 1 to 5 V, 4 to 20 mA, TC, R, and RTD | Yes; only for 1 ... 5 V and 4 ... 20 mA | Yes; only for 1 ... 5 V and 4 ... 20 mA | |
| Yes | Yes | Yes | Yes | |
Diagnostics indication LED |
|
|
|
| |
| Yes; Green LED | Yes; Green LED | Yes; Green LED | Yes; Green LED | |
| Yes; Red LED | Yes; Red LED | Yes; Red LED | Yes; Red LED | |
| Yes; Green LED | Yes; Green LED | Yes; Green LED | Yes; Green LED | |
| Yes; Green LED | Yes; Green LED | Yes; Green LED | Yes; Green LED | |
| Yes; Red LED | Yes; Red LED | Yes; Red LED | Yes; Red LED | |
| Yes; Red LED | Yes; Red LED | Yes; Red LED | Yes; Red LED | |
Potential separation |
|
|
|
| |
Potential separation channels |
|
|
|
| |
| No | No | No | Yes | |
| 4 | 8 | 8 | 1 | |
| Yes | Yes | Yes | Yes | |
| Yes | Yes | Yes | Yes | |
Permissible potential difference |
|
|
|
| |
between different circuits |
|
|
| 60 V DC/30 V AC; insulation rated for 120 V AC basic insulation: between the channels and the supply voltage L+; between the channels and the backplane bus; between the channels | |
between the inputs (UCM) | 20 V DC | 20 V DC | 20 V DC |
| |
Between the inputs and MANA (UCM) | 10 V DC | 10 V DC | 10 V DC |
| |
Isolation |
|
|
|
| |
Isolation tested with | 707 V DC (type test) | 707 V DC (type test) | 707 V DC (type test) | 2 000 V DC between the channels and the supply voltage L+; 2 000 V DC between the channels and the backplane bus; 2 000 V DC between the channels; 707 V DC (type test) between the supply voltage L+ and the backplane bus | |
Ambient conditions |
|
|
|
| |
Ambient temperature during operation |
|
|
|
| |
| 0 °C | 0 °C | 0 °C | 0 °C | |
| 60 °C | 60 °C | 60 °C | 60 °C | |
| 0 °C | 0 °C | 0 °C | 0 °C | |
| 40 °C | 40 °C | 40 °C | 40 °C | |
Decentralized operation |
|
|
|
| |
Prioritized startup | No | No | Yes | Yes | |
Dimensions |
|
|
|
| |
Width | 25 mm | 35 mm | 35 mm | 35 mm | |
Height | 147 mm | 147 mm | 147 mm | 147 mm | |
Depth | 129 mm | 129 mm | 129 mm | 129 mm | |
Weights |
|
|
|
| |
Weight, approx. | 210 g | 310 g | 300 g | 280 g | |
Other |
|
|
|
| |
Note: | Supplied incl. 40-pole push-in front connectors. Additional basic error and noise for integration time = 2.5 ms: Voltage: ±250 mV (±0.02%), ±80 mV (±0.05%), ±50 mV (±0.05%); resistance: 150 Ohms (±0.02%); resistance thermometer: Pt100 climate: ±0.08 K, Ni100 climate: ±0.08 K; thermoelement: Type B, R, S: ±3 K, type E, J, K, N, T: ±1 K | Additional basic error and noise for integration time = 2.5 ms: Voltage: ±250 mV (±0.02%), ±80 mV (±0.05%), ±50 mV (±0.05%); resistance: 150 ohms ±0.02%; resistance thermometer: Pt100 climate: ±0.08 K, Ni100 climate: ±0.08 K; thermocouple: Type B, R, S: ±3 K, type E, J, K, N, T: ±1 K |
|
|
Article number | 6ES7531-7PF00-0AB0 | |
---|---|---|
| S7-1500, AI 8 X U/R/RTD/TC HF | |
General information |
| |
Product type designation | AI 8xU/R/RTD/TC HF | |
HW functional status | FS01 | |
Firmware version | V1.1.0 | |
| Yes | |
Product function |
| |
| Yes; I&M0 to I&M3 | |
| Yes | |
| No | |
| No | |
Engineering with |
| |
| V14 / - | |
| V5.5 SP3 / - | |
| V1.0 / V5.1 | |
| V2.3 / - | |
Operating mode |
| |
| No | |
| Yes | |
CiR – Configuration in RUN |
| |
Reparameterization possible in RUN | Yes | |
Calibration possible in RUN | Yes | |
Supply voltage |
| |
Rated value (DC) | 24 V | |
permissible range, lower limit (DC) | 20.4 V | |
permissible range, upper limit (DC) | 28.8 V | |
Reverse polarity protection | Yes | |
Input current |
| |
Current consumption, max. | 55 mA; with 24 V DC supply | |
Power |
| |
Power available from the backplane bus | 0.85 W | |
Power loss |
| |
Power loss, typ. | 1.9 W | |
Analog inputs |
| |
Number of analog inputs | 8; Plus one additional RTD (reference) channel | |
| 8; Plus one additional RTD (reference) channel | |
| 8; Plus one additional RTD (reference) channel | |
| 8; Plus one additional RTD (reference) channel | |
permissible input voltage for voltage input (destruction limit), max. | 20 V | |
Technical unit for temperature measurement adjustable | Yes; °C/°F/K | |
Input ranges (rated values), voltages |
| |
| No | |
| No | |
| No | |
| Yes | |
| 10 M? | |
| No | |
| No | |
| Yes | |
| 10 M? | |
| Yes | |
| 10 M? | |
| No | |
| Yes | |
| 10 M? | |
| Yes | |
| 10 M? | |
| Yes | |
| 10 M? | |
Input ranges (rated values), currents |
| |
| No | |
| No | |
| No | |
Input ranges (rated values), thermocouples |
| |
| Yes | |
| 10 M? | |
| Yes | |
| 10 M? | |
| Yes | |
| 10 M? | |
| Yes | |
| 10 M? | |
| Yes | |
| 10 M? | |
| No | |
| Yes | |
| 10 M? | |
| Yes | |
| 10 M? | |
| Yes | |
| 10 M? | |
| Yes | |
| 10 M? | |
| Yes | |
| 10 M? | |
Input ranges (rated values), resistance thermometer |
| |
| Yes; Standard/climate | |
| 10 M? | |
| Yes; Standard/climate | |
| 10 M? | |
| Yes; Standard/climate | |
| 10 M? | |
| Yes; Standard/climate | |
| 10 M? | |
| Yes; Standard/climate | |
| 10 M? | |
| Yes; Standard/climate | |
| 10 M? | |
| Yes; Standard/climate | |
| 10 M? | |
| Yes; Standard/climate | |
| 10 M? | |
| Yes; Standard/climate | |
| 10 M? | |
| Yes; Standard/climate | |
| 10 M? | |
| Yes; Standard/climate | |
| 10 M? | |
| Yes; Standard/climate | |
| 10 M? | |
| Yes; Standard/climate | |
| 10 M? | |
| Yes; Standard/climate | |
| 10 M? | |
| Yes; Standard/climate | |
| 10 M? | |
| Yes; Standard/climate | |
| 10 M? | |
| Yes; Standard/climate | |
| 10 M? | |
| Yes; Standard/climate | |
| 10 M? | |
| Yes; Standard/climate | |
| 10 M? | |
| Yes; Standard/climate | |
| 10 M? | |
| Yes; Standard/climate | |
| 10 M? | |
| Yes; Standard/climate | |
| 10 M? | |
| Yes; Standard/climate | |
| 10 M? | |
| Yes; Standard/climate | |
| 10 M? | |
| Yes; Standard/climate | |
| 10 M? | |
| Yes; Standard/climate | |
| 10 M? | |
| Yes; Standard/climate | |
| 10 M? | |
| Yes; Standard/climate | |
| 10 M? | |
| Yes; Standard/climate | |
| 10 M? | |
| Yes; Standard/climate | |
| 10 M? | |
| Yes; Standard/climate | |
| 10 M? | |
Input ranges (rated values), resistors |
| |
| Yes | |
| 10 M? | |
| Yes | |
| 10 M? | |
| Yes | |
| 10 M? | |
| No | |
| Yes | |
| 10 M? | |
| Yes | |
| 10 M? | |
Thermocouple (TC) |
| |
Temperature compensation |
| |
| Yes | |
| Yes | |
| Yes | |
| Yes; fixed value can be set | |
| Yes; 9th channel that can be used as a genuine 9th RTD channel regardless of the parameterization of the other channels, or that can be used for compensation in the case of TC measurement | |
Cable length |
| |
| 800 m; at U; 200 m at R/RTD/TC | |
Analog value generation for the inputs |
| |
Integration and conversion time/resolution per channel |
| |
| 21 bit; For measuring mode RTC and TC when using the function "Scalable temperature measuring range" (32-bit REAL format); 16-bit for measuring mode R and U; 16 bit for all measuring modes when using the S7 format (16-bit INTEGER) | |
| Yes | |
| Fast mode: 2.5 / 16.67 / 20 / 100 ms, standard mode: 7.5 / 50 / 60 / 300 ms | |
| Fast mode: 4 / 18 / 22 / 102 ms; Standard mode: 9 / 52 / 62 / 302 ms | |
| Thermocouples, 150 Ohm, 300 Ohm, 600 Ohm, Cu10, Cu50, Cu100, Ni10, Ni50, Ni100, Ni120, Ni200, Pt10, Pt50, Pt100, Pt200: 4 ms; 6 kOhm, Ni500, Ni1000, LG-Ni1000, Pt500, Pt1000: 13 ms | |
| 400 / 60 / 50 / 10 Hz | |
| Corresponds to the channel with the highest basic conversion time | |
Smoothing of measured values |
| |
| Yes | |
| Yes | |
| Yes | |
| Yes | |
| Yes | |
Encoder |
| |
Connection of signal encoders |
| |
| Yes | |
| No | |
| No | |
| Yes | |
| Yes; All measuring ranges except PTC; internal compensation of the cable resistances | |
| Yes; All measuring ranges except PTC | |
Errors/accuracies |
| |
Linearity error (relative to input range), (+/-) | 0.02 % | |
Temperature error (relative to input range), (+/-) | 0.005 %/K | |
Crosstalk between the inputs, max. | -80 dB | |
Repeat accuracy in steady state at 25 °C (relative to input range), (+/-) | 0.02 % | |
Temperature error of internal compensation | ±1,5 °C | |
Operational error limit in overall temperature range |
| |
| 0.1 % | |
| 0.1 % | |
| Cuxxx Standard: ±0.5 K, Cuxxx Klima: ±0.5 K, Ptxxx Standard: ±1 K, Ptxxx Klima: ±0.5 K, Nixxx Standard: ±0.5 K, Nixxx Klima: ±0.3 K | |
| Type B: > 600 °C ±2 K, Type E: > -200 °C ±1 K, Type J: > -210 °C ±1 K, Type K: > -200 °C ±2 K, Type N: > -200 °C ±2 K, Type R: > 0 °C ±2 K, Type S: > 0 °C ±2 K, Type T: > -200 °C ±1 K, Type C: ±4 K, Type TXK/TXK(L): ±1 K | |
Basic error limit (operational limit at 25 °C) |
| |
| 0.05 % | |
| 0.05 % | |
| Cuxxx Standard: ±0.3 K, Cuxxx Klima: ±0.2 K, Ptxxx Standard: ±0.5 K, Ptxxx Klima: ±0.2 K, Nixxx Standard: ±0.3 K, Nixxx Klima: ±0.15 K | |
| Type B: > 600 °C ±1 K, Type E: > -200 °C ±0.5 K, Type J: > -210 °C ±0.5 K, Type K: > -200 °C ±1 K, Type N: > -200 °C ±1 K, Type R: > 0 °C ±1 K, Type S: > 0 °C ±1 K, Type T: > -200 °C ±0.5 K, Type C: ±2 K, Type TXK/TXK(L): ±0.5 K | |
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency |
| |
| 80 dB; in the Standard operating mode, 40 dB in the Fast operating mode | |
| 60 V DC/30 V AC | |
| 80 dB | |
Isochronous mode |
| |
Isochronous operation (application synchronized up to terminal) | No | |
Interrupts/diagnostics/status information |
| |
Diagnostics function | Yes | |
Alarms |
| |
| Yes | |
| Yes; two upper and two lower limit values in each case | |
Diagnostic messages |
| |
| Yes | |
| Yes; Only with TC, R, RTD | |
| Yes | |
Diagnostics indication LED |
| |
| Yes; Green LED | |
| Yes; Red LED | |
| Yes; Green LED | |
| Yes; Green LED | |
| Yes; Red LED | |
| Yes; Red LED | |
Potential separation |
| |
Potential separation channels |
| |
| Yes | |
| 1 | |
| Yes | |
| Yes | |
Permissible potential difference |
| |
between different circuits | 60 V DC/30 V AC; insulation rated for 120 V AC basic insulation: between the channels and the supply voltage L+; between the channels and the backplane bus; between the channels | |
Isolation |
| |
Isolation tested with | 2 000 V DC between the channels and the supply voltage L+; 2 000 V DC between the channels and the backplane bus; 2 000 V DC between the channels; 707 V DC (type test) between the supply voltage L+ and the backplane bus | |
Ambient conditions |
| |
Ambient temperature during operation |
| |
| 0 °C | |
| 60 °C | |
| 0 °C | |
| 40 °C | |
Decentralized operation |
| |
Prioritized startup | Yes | |
Dimensions |
| |
Width | 35 mm | |
Height | 147 mm | |
Depth | 129 mm | |
Weights |
| |
Weight, approx. | 290 g | |
Other |
| |
Note: | For the R/RDT three-wire measurement, the conductor compensation is made alternating with the measurement. This then requires two module cycles for a measured value. |
統(tǒng)一的顯示和診斷方式:
支持的功能: 持續(xù)穩(wěn)定的 16 位高分辨率 識(shí)別和維護(hù)數(shù)據(jù) IM0 至 IM3 固件更新 與通道相關(guān)的參數(shù)分配 硬件中斷;可設(shè)置兩個(gè)上限值和下限值 按通道診斷(取決于測(cè)量類型/測(cè)量范圍) 等時(shí)同步模式(取決于模塊) 在運(yùn)行過程中進(jìn)行校準(zhǔn)
含在供貨范圍之內(nèi):
電源元件、屏蔽支架和屏蔽端子 用于手工貼標(biāo)簽的一個(gè)標(biāo)簽條 一個(gè) U 型連接器 印制有文字的前門
用一個(gè)螺絲安裝在 S7-1500 安裝導(dǎo)軌上 35 mm 模塊 采用螺釘型端子或推入式端子的標(biāo)準(zhǔn)化 40 針前連接器(不能用于 25 mm 模塊) 25 mm 模塊 采用推入式端子的標(biāo)準(zhǔn)化 40 針前連接器(不能用于 35 mm 模塊) 可連接芯線截面積 0.25 mm2 - 1.5 mm2(AWG24 至 16),無論使用何種前連接器 前連接器的預(yù)接線位置 前蓋帶有可擴(kuò)充的電纜室,即使*接線時(shí)也如此 集成式屏蔽 模塊正面的清晰標(biāo)簽
模擬量輸入模塊可以記錄壓力或溫度等過程信號(hào),并以數(shù)字形式(16 位形式)將它們傳送給控制器。這些模塊適用于測(cè)量電流(2 線制和 4 線制傳感器)、電壓和電阻,并適合連接電阻溫度計(jì)和熱電偶(測(cè)量類型取決于模塊)。
提供有以下模擬量輸入模塊:
AI 4xU/I/RTD/TC ST
帶有 4 個(gè)通道的模擬量輸入模塊;分辨率 16 位;準(zhǔn)確度 +/-0.3%;一個(gè)電位組;共模電壓 10 V;可設(shè)置診斷參數(shù);硬件中斷(兩個(gè)上限和下限);在執(zhí)行期間進(jìn)行校準(zhǔn)。
模塊寬度 25 mm AI 8xU/I/RTD/TC ST
帶有 8 個(gè)通道的模擬量輸入模塊;分辨率 16 位;準(zhǔn)確度 +/-0.3%;一個(gè)電位組;共模電壓 10 V;可設(shè)置診斷參數(shù);硬件中斷(兩個(gè)上限和下限);在執(zhí)行期間進(jìn)行校準(zhǔn)。
模塊寬度 35 mm AI 8xU/I HS
模擬量輸入模塊,帶 8 個(gè)通道;分辨率 16 位;準(zhǔn)確度 +/-0.3%; 一個(gè)電壓組;共模電壓 10 V;可設(shè)置診斷參數(shù);硬件中斷(兩個(gè)上限和下限);8 通道高速模塊,125 µs;等時(shí)同步模式;在執(zhí)行期間進(jìn)行校準(zhǔn)
模塊寬度 35 mm