河南兆陽自動(dòng)化科技有限公司>>技術(shù)文章>>西門子G120功率模塊PM250D6SL3525-0PE23-0AA1

西門子G120功率模塊PM250D6SL3525-0PE23-0AA1

閱讀:412        發(fā)布時(shí)間:2019-7-5

西門子G120功率模塊PM250D6SL3525-0PE23-0AA1

6SL3525-0PE23-0AA1

Product

相似圖像

SINAMICS G120D 功率模塊 PM250D 帶集成式 A 類濾波器 能量回饋 380-480V+10/-10% 三相交流 47-63Hz 重過載功率:3.0kW 當(dāng) 200% 3S,150% 60S, 100% 300S 環(huán)境溫度 -10 至 +55°C 210x 450x 180(高x寬x深),FSB 防護(hù)等級(jí) IP65 無 控制單元

列表價(jià)(不含稅)顯示價(jià)格 
您的單價(jià)(不含稅)顯示價(jià)格 
PDF 格式的數(shù)據(jù)表下載
服務(wù)和支持 (手冊(cè),認(rèn)證,問答...)下載

更多圖片

產(chǎn)品
商品編號(hào)(市售編號(hào))6SL3525-0PE23-0AA1
產(chǎn)品說明SINAMICS G120D 功率模塊 PM250D 帶集成式 A 類濾波器 能量回饋 380-480V+10/-10% 三相交流 47-63Hz 重過載功率:3.0kW 當(dāng) 200% 3S,150% 60S, 100% 300S 環(huán)境溫度 -10 至 +55°C 210x 450x 180(高x寬x深),FSB 防護(hù)等級(jí) IP65 無 控制單元
產(chǎn)品家族未提供
產(chǎn)品生命周期 (PLM)PM300:有效產(chǎn)品
價(jià)格數(shù)據(jù)
價(jià)格組 / 總部價(jià)格組346
列表價(jià)(不含稅)顯示價(jià)格
您的單價(jià)(不含稅)顯示價(jià)格
金屬系數(shù)
交付信息
出口管制規(guī)定ECCN : N / AL : N
工廠生產(chǎn)時(shí)間3 天
凈重 (Kg)8 Kg
產(chǎn)品尺寸 (W x L X H)未提供
包裝尺寸250.00 x 525.00 x 295.00
包裝尺寸單位的測量MM
數(shù)量單位1 件
包裝數(shù)量1
其他產(chǎn)品信息
EAN4019169458603
UPC 
商品代碼85044084
LKZ_FDB/ CatalogIDD11.1SD
產(chǎn)品組2245
原產(chǎn)國英國
Compliance with the substance restrictions according to RoHS directiveRoHS 合規(guī)開始日期: 2006.07.01
產(chǎn)品類別A: 問題無關(guān),即刻重復(fù)使用
電氣和電子設(shè)備使用后的收回義務(wù)類別
REACH Art. 33 責(zé)任信息

Lead > 0, 1 % (w / w)

分類
 未提供

 | 

其它文件

建議同時(shí)購買:

  6SL3544-0FB20-1FA0

SINAMICS G120D 控制單元 CU240D-2 PN PROFINET,STO 機(jī)載 6 DI/1 F-DI,2 個(gè)數(shù)字輸出,2 AI USB 接口 SD/MMC-卡-接口 HTL 編碼器接口 防護(hù)等級(jí) IP65 環(huán)境溫度 -10 至 +50°C 無功率模塊

  6SL3525-0PE27-A1

SINAMICS G120D 功率模塊 PM250D 帶集成式 A 類濾波器 能量回饋 380-480V+10/-10% 三相交流 47-63Hz 重過載功率:7.5kW 當(dāng) 200% 3S,150% 60S, 100% 300S 環(huán)境溫度 -10 至 +55°C 210x 450x 220(高x寬x深),FSC 防護(hù)等級(jí) IP65 無 控制單元

  6SL3525-0PE24-0AA1

SINAMICS G120D 功率模塊 PM250D 帶集成式 A 類濾波器 能量回饋 380-480V+10/-10% 三相交流 47-63Hz 重過載功率:4.0kW 當(dāng) 200% 3S,150% 60S, 100% 300S 環(huán)境溫度 -10 至 +55°C 210x 450x 220(高x寬x深),FSC 防護(hù)等級(jí) IP65 無 控制單元

  6SL3546-0FB21-1FA0

SINAMICS G120D 控制單元 CU250D-2 PN-F PROFINET 和 Safety integrated 具有定位能力(EPOS) 6 DI/3 F-DI,2 DO/1 F-DO,2 AI USB 接口 SD/MMC-卡-接口 HTL 和 SSI 編碼器接口 防護(hù)等級(jí) IP65 環(huán)境溫度 -10 至 +50°C 無功率模塊

  1FK7032-2AK71-1EH2

100K, 6000rpm, 0.50kW自冷卻式 IM B5(IM V1,IM V3) 功率插頭/信號(hào)插頭 結(jié)構(gòu) IMB 5(IM V1,IM V3) 法蘭 1,帶 KTY 溫度傳感器 功率連接器可旋轉(zhuǎn) 值編碼器 2048 S/R+ 4096 轉(zhuǎn)多匝 帶 EnDat 接口 (編碼器 AM2048S/R) 光滑的軸,公差 N 帶駐車制動(dòng)器 防護(hù)等級(jí) IP65 DE 法蘭 IP67

 西門子G120功率模塊PM250D6SL3525-0PE23-0AA1

The PM240?2 and PM250 Power Modules are already designed for Safety Integrated.

In conjunction with a standard Control Unit, the drive provides the safety function STO.
The PM240?2 Power Modules, frame sizes FSD to FSG additionally offer STO acc. to IEC 61508 SIL 3 and EN ISO 13489?1 PL e and Category 3.

In conjunction with a fail-safe Control Unit, the drive can be turned into a Safety Integrated Drive with comprehensive safety functions.

The Safety Integrated functions are fully integrated in the drive system. They can be activated via fail-safe digital inputs or via PROFINET or PROFIBUS with PROFIsafe.

The Safety Integrated functions are implemented electronically and therefore offer short response times compared to solutions with externally implemented monitoring functions.

Safety Integrated encoderless

The safety functions do not require a motor encoder; the implementation effort is minimal. Existing machines in particular can be updated with integrated safety technology without the need to change the motor or mechanical system.

The STO function can be used without any restrictions for all applications.

The SS1, SLS, SSM and SDI functions are only permissible for applications where the load can never cause acceleration. An encoder that is used for the purposes of motor control has no significance for the safety functions here.

Safety Integrated overview

The availability of Safety Integrated functions depends on the type of Control Unit. Standard Control Units and fail-safe Control Units are available.

The CU240E?2 standard Control Units have STO and the CU250S?2 Control Units have STO, SBC, and SS1 as standard.

The fail-safe Control Units offer Extended Functions (SLS, SDI, SSM) in addition to the Basic Functions (STO, SS1). The Basic Function SBC is currently supported by the CU250S?2.

A license is required for operation of the Extended Functions on the CU250S?2 Control Unit. It is of no consequence here which safety functions are used and how many.

The license can be ordered as an option with the memory card. Alternatively, a single-user license can also be purchased.

Safe Brake Relay

The Safe Brake Control (SBC) function requires a Safe Brake Relay. The Safe Brake Relay allows safe control of electro-mechanical motor brakes.

The 24 V DC solenoid of the motor brake is directly connected to the Safe Brake Relay. External surge suppressors are not required. The cable harnesses for connection to the Power Module are included in the scope of supply.

With the Safe Brake Relay function, the brake is controlled in accordance with IEC 61508 SIL 2 and EN ISO 13849?1 PL d and Category 3.

優(yōu)勢

Comparison between conventional and integrated safety systems

The safety functions integrated into the drive can greatly reduce the effort required to implement safety concepts.

The integrated safety functions provide support when setting up tailored safety concepts. Configurations of safety concepts are given below based on the example of the SINAMICS G120.

Safe Torque Off (STO)

Classic implementation using an external circuit

Standalone safety solution via fail-safe inputs

Integrated safety solution via PROFIsafe

Safe S (SS1)

Classic implementation using an external circuit

Standalone safety solution via fail-safe inputs

Integrated safety solution via PROFIsafe

Safely-Limited Speed (SLS)

Classic implementation using an external circuit

Standalone safety solution via fail-safe inputs

Integrated safety solution via PROFIsafe

 

 

6SL3054-4AG00-2AA0

SINAMICS 512MB SD 卡,空

顯示價(jià)格

 
組態(tài)
 
 
 

6SL3054-7TF00-2BA0

SINAMICS G120 SD 卡 512 MByte 包括發(fā)給許可證 (許可證) V4.7 SP10 HF4

顯示價(jià)格

 
組態(tài)
 
 
 

6SL3074-0AA10-0AA0

SINAMICS 許可證 安全整合 擴(kuò)展功能 用于存儲(chǔ)卡

顯示價(jià)格

 
 
 
 
 

6SL3074-7AA04-0AA0

SINAMICS G120 許可證,擴(kuò)展功能 用于存儲(chǔ)卡 (CU250S-2 矢量) 用于功能性:EPos

顯示價(jià)格

 
 
 
 
 

6SL3243-0BB30-1FA0

SINAMICS G120 控制單元 CU230P-2 PN 集成 PROFINET 6 DI,3 DO,4 模擬輸入,2 個(gè)模擬輸出 1 個(gè)電機(jī)溫度 傳感器輸入端 2 PSU-out(10V DC,24V DC) 1 PSU-in(24V DC) USB- 和 MMC-接口 防護(hù)等級(jí) IP20

顯示價(jià)格

 
組態(tài)
 
 
 

6SL3243-0BB30-1HA3

SINAMICS G120 控制單元 CU230P-2 HVAC USS/MODBUS RTU/BACnet MS/TP 6 DI,3 DO,4 模擬輸入,2 個(gè)模擬輸出 1 個(gè)電機(jī)溫度 傳感器輸入端 2 PSU-out(10V DC,24V DC) 1 PSU-in(24V DC) USB- 和 MMC-接口 防護(hù)等級(jí) IP20

顯示價(jià)格

 
組態(tài)
 
 
 

6SL3243-0BB30-1PA3

SINAMICS G120 控制單元 CU230P-2 DP 集成 PROFIBUS-DP 6 DI,3 DO,4 模擬輸入,2 個(gè)模擬輸出 1 個(gè)電機(jī)溫度 傳感器輸入端 2 PSU-out(10V DC,24V DC) 1 PSU-in(24V DC) USB- 和 MMC-接口 防護(hù)等級(jí) IP20

顯示價(jià)格

 
組態(tài)
 
 
 

6SL3244-0BB00-1BA1

SINAMICS G120 控制單元 CU240B-2 B-型 RS-485-接口使用 USS-/MODBUS RTU-協(xié)議 4 DI,1 個(gè)數(shù)字輸出 ,1 個(gè)模擬輸入,1 AO PTC/KTY/Thermoclick 接口 USB 和 SD/MMC 接口 防護(hù)等級(jí) IP20 環(huán)境溫度 0 至 +50°C 無功率模塊

顯示價(jià)格

 
組態(tài)
 
 
 

6SL3244-0BB00-1PA1

SINAMICS G120 控制單元CU240B-2 DP B-型 PROFIBUS-DP 4 DI,1 個(gè)數(shù)字輸出 ,1 個(gè)模擬輸入,1 AO PTC/KTY/Thermoclick 接口 USB 和 SD/MMC 接口 防護(hù)等級(jí) IP20 環(huán)境溫度 0 至 +50°C 無功率模塊

顯示價(jià)格

 
組態(tài)
 
 
 

6SL3244-0BB12-1BA1

SINAMICS G120 控制單元 CU240E-2 E-型配備安全集成 STO RS-485-接口,USS-協(xié)議 6DI,3DO,2AI,2AO,大 1F-DI PTC/KTY 接口 USB 和 SD/MMC 接口 防護(hù)等級(jí) IP20 環(huán)境溫度 0 至 +50°C 無功率模塊

 

 

CU230P?2 Control Units

CU230P?2 PN Control Unit

The Control Unit performs closed-loop control functions for the converter.

The CU230P-2 Control Units are designed for drives with integrated technological functions for pump, fan and compressor applications.

The I/O interface, the fieldbus interfaces and the additional software functions optimally support these applications. The integration of technological functions is a significant differentiating feature to the other Control Units of the SINAMICS G120 drive family.

The CU230P-2 Control Units can be operated with the following Power Modules:

  • PM240?2
  • PM250

Note:

Shield plates and shield connection kits are available for use in the wiring installation of Control Units and Power Modules to ensure that it complies with EMC guidelines. 
For more information about shield connection kits and shield plates for Control Units and Power Modules, please refer to section Supplementary system components.

Typical, integrated HVAC/HLK functions

  • Linear and quadratic torque characteristic for fluid flow and positive displacement machines
  • ECO mode for additional energy saving in V/f control mode
  • 2 analog inputs (current/voltage can be selected) to directly connect pressure/level sensors
  • 2 additional analog inputs to connect Pt1000/LG?Ni1000/DIN?Ni1000 temperature sensors
  • Direct control of valves and flaps using two 230 V AC relays
  • Automatic restart
  • Flying restart
  • Skip frequencies
  • Hibernation mode
  • Load check function to monitor belts and flow
  • Cascade connection
  • 4 integrated PID controllers (e.g. for temperature, pressure, air quality, level)
  • Multi-zone controller
  • Essential service mode
  • Real time clock with three time generators

IOP?2 wizards for special applications

  • Pumps: Positive displacement (constant load torque) and centrifugal pumps (square load torque) with and without PID controller
  • Fans: Radial and axial fans (square load torque) with and without PID controller
  • Compressors: Positive displacement (constant load torque) and fluid flow machines (square load torque) with and without PID controller

Control Unit CU240E?2

CU240E?2 DP?F Control Unit

The Control Unit performs closed-loop control functions for the converter.

The CU240E?2 Control Unit is designed as standard Control Unit for all of the usual applications involving V/f or vector control.

  • CU240E-2 series with standard I/O quantity structure and integrated safety technology

The CU240E?2 Control Unit can be combined with the following Power Modules:

  • PM240?2
  • PM250

Note:

Shield plates and shield connection kits are available for use in the wiring installation of Control Units and Power Modules to ensure that it complies with EMC guidelines. 
For more information about shield connection kits and shield plates for Control Units and Power Modules, please refer to section Supplementary system components.

Safety Integrated functions

The safety function "Safe Torque Off" (STO) (certified according to IEC 61508 SIL 2 and EN ISO 13849?1 PL d and Category 3) is already integrated into the basic versions of the CU240E?2 series (CU240E?2, CU240E?2 DP, CU240E?2 PN).

With the fail-safe variants of the CU240E-2 series (CU240E?2 F, CU240E?2 DP-F, CU240E?2 PN-F), the fail-safe SINAMICS G120 converter provides five safety functions which are certified according to IEC 61508 SIL 2 and EN ISO 13849?1 PL d and Category 3:

  • Safe Torque Off (STO)
    to protect against active movement of the drive
  • Safe Stop 1 (SS1)
    for continuous monitoring of a safe braking ramp
  • Safely-Limited Speed (SLS)
    for protection against dangerous movements when a speed limit is exceeded (the CU240E?2 DP Failsafe Control Unit has 4 selectable SLS limit values)
  • Safe Direction (SDI)
    This function ensures that the drive can only rotate in the selected direction.
  • Safe Speed Monitor (SSM)
    This function signals if a drive operates below a specific speed/feed velocity (CU240E?2 DP?F / CU240E?2 PN?F with PROFIsafe).

These functions can be activated by means of PROFIsafe or via the safety inputs.

None of the safety functions require a motor encoder and they are thus much cheaper and easier to implement. Existing systems in particular can be simply updated with safety technology without the need to change the motor or mechanical system.

The Safe Torque Off (STO) function can be used without restriction for all applications. The SS1, SLS, SDI and SSM functions are only permissible for applications where the load can never accelerate when the converter is switched off. They are therefore not permitted for applications involving pull-through loads such as hoisting gear and unwinders.

Further information can be found in the section Safety Integrated.

CU250S?2 Control Units

CU250S-2 Control Unit

The Control Unit performs closed-loop control functions for the converter.

The CU250S?2 Control Units are designed as standard Control Units for all of the usual applications involving V/f or vector control.

CU250S?2 Control Units can be used to implement all common applications involving V/f or vector control as well as applications for drives with positioning requirements. This expansion allows them to be used in lifting, swiveling, traversing or rotating applications. The positioning functionality is comparable with SINAMICS S110 servo drives.

Two points must be noted here:

  • Vector control (VC) and sensorless vector control (SLVC) are possible
  • Encoder possible for speed and position control (positioning)

The CU250S?2 Control Units can be combined with the following Power Modules:

  • PM240?2
  • PM250

Note:

Shield plates and shield connection kits are available for use in the wiring installation of Control Units and Power Modules to ensure that it complies with EMC guidelines.

For more information about shield connection kits and shield plates for Control Units and Power Modules, please refer to section Supplementary system components.

Safety Integrated functions

The following Safety Integrated Basic Functions (certified according to IEC 61508 SIL 2 and EN ISO 13849?1 PL d and Category 3) are integrated as standard in the CU250S-2 series:

  • Safe Torque Off (STO)
    to protect against active movement of the drive
  • Safe Stop 1 (SS1)
    for continuous monitoring of a safe braking ramp
  • Safe Brake Control (SBC) is used to safely control a holding
    brake

The following Safety Integrated Extended Functions (certified according to IEC 61508 SIL 2 and EN ISO 13849?1 PL d and Category 3) are optionally available for the CU250S-2 series:

  • Safely-Limited Speed (SLS)
    for protection against dangerous movements when a speed limit is exceeded
  • Safe Direction (SDI)
    This function ensures that the drive can only rotate in the selected direction.
  • Safe Speed Monitor (SSM)
    This function signals if a drive operates below a specific speed/feed velocity.

These functions can be activated by means of PROFIsafe or via the safety inputs.

None of the safety functions require a motor encoder and they are thus much cheaper and easier to implement. Existing systems in particular can be simply updated with safety technology without the need to change the motor or mechanical system.

The Safe Torque Off (STO) function can be used without restriction for all applications. The SS1, SLS, SDI and SSM functions are only permissible for applications where the load can never accelerate when the converter is switched off. They are therefore not permitted for applications involving pull-through loads such as hoisting gear and unwinders.

Further information can be found in the section Safety Integrated.

設(shè)計(jì)

CU230P?2 HVAC, CU230P?2 DP and CU230P?2 PN Control Units

CU230P?2 Control Unit with open and closed terminal covers

收藏該商鋪