應(yīng)用領(lǐng)域 | 地礦 |
---|
流量開關(guān)
FF 015RMS-125 / -138
●調(diào)整后的開關(guān)值
●高度可復(fù)制
●對污垢不敏感
特點
體積流將活塞(裝有磁鐵)從
閥座抵抗彈簧力?;钊聞?
![]() |
參考價 | 面議 |
更新時間:2021-01-13 13:15:54瀏覽次數(shù):299
聯(lián)系我們時請說明是化工儀器網(wǎng)上看到的信息,謝謝!
FF-015RMS-138
Flow Switch FF-015RMS-125/-138 ● Adjusted switching value ● Highly reproducible ● Insensitive to dirt Characteristics The volume flow raises a piston (fitted with a magnet) out from a valve seat against a spring force. The piston actuates a hermetically separated reed switch. Technical data Switch reed switch Process connection male thread 1“-14UNS Adjustment for details see Q table "Adjustment" max. Tolerance ±3 % of the switching value, minimum ±0.3 l/min Pressure resistance PN 200 bar Medium temperature -20..+100 °C Ambient temperature -20..+70 °C Media water (oils available on request) Wiring normally open (n.o.) no. 0.212 Switching voltage max. 230 V AC Switching current max. 1 A Switching capacity max. 50 VA Protection class 1 - PE connection Ingress protection IP 65 Electrical connection silicon cable 0,95 m Materials medium-contact CW614N, CR 70, CuSn 8, hard ferrite Non-mediumcontact materials PA, PVC, Silicon Weight see table "Dimensions and weights" Installation location Standard: horizontal inwards flow; switching head not recommended underneath; other installation positions are possible; the installation position affects the switching point and range. Adjustment Details in the table correspond to horizontal inwards flow with decreasing flow rate. UNS DN Switching point l/min H2O Types Qmax. recommended 1“-14 UNS DN 15 6 FF-015RMS-138 20 1“-14 UNS DN 15 10 FF-015RMS-125 20