當(dāng)前位置:北京豫維科技有限公司>>氣相色譜配件>>通用色譜配件>>GC 柱溫箱加速插入套件-用于Agilent

GC 柱溫箱加速插入套件-用于Agilent

參   考   價:面議
具體成交價以合同協(xié)議為準(zhǔn)

產(chǎn)品型號:

品       牌:RESTEK/瑞思泰康

廠商性質(zhì):代理商

所  在  地:北京市

更新時間:2019-01-25 15:39:13瀏覽次數(shù):1221

聯(lián)系我時,請告知來自 化工儀器網(wǎng)
供貨周期 現(xiàn)貨 貨號 23849
GC 柱溫箱加速插入套件-用于Agilent
Get the same GC separation in less time—use a GC Accelerator kit and the EZGC method translator to accurately convert methods to a scaled-down column format.

GC 柱溫箱加速插入套件-用于Agilent 6890和7890儀器

  • Get the same GC separation in less time—use a GC Accelerator kit and the EZGC method translator to accurately convert methods to a scaled-down column format.

  • Scaled-down methods let you speed up analysis time and increase sample throughput without capital investment.

  • GC Accelerator kit installs easily without damaging the GC column or interfering with the MS interface.

Designed with GC-MS users in mind, the GC Accelerator kit provides a simple way to speed up sample analysis. By reducing oven volume, these inserts allow faster ramp rates to be attained, which reduces oven cycle time and allows for increased sample throughput and more capacity to process rush samples. When faster ramp rates are used, existing methods can be accurately scaled down to smaller, high-efficiency, narrow-bore columns using Restek’s EZGC method translator. With a scaled-down column, a properly translated method, and a GC Accelerator kit, you can obtain the same chromatographic separation—often with greater sensitivity—in a fraction of the time without making a capital investment.

 

訂貨信息:

GC 柱溫箱加速插入套件-用于Agilent 6890和7890儀器

描述貨號
GC 柱溫箱加速插入套件23849

 

GC Accelerator Use

Installation

  1. Turn off the oven and wait until the oven, inlets, detectors, and MS transfer line have cooled.

  2. Ensure the column and the column hanger are in the back position in the oven

  3. If no detector is in the front position, install the two block inserts in front of the column as shown in Figure 2. If there is a detector in the front position, install the two block inserts in front of the column as shown in Figure 3.

Caution: The block inserts should not touch the analytical column or the MSD source nut (Figure 4).

4. Install the plate insert in the front of the oven so that the front is flush with the edge of the oven (Figure 5).

 

Removal

Turn off the oven and wait until all oven, inlets, detectors, and MS transfer line surfaces have cooled.

Caution: To avoid burns, use the strap to remove the plate insert or wear heat-resistant gloves. The metal fasteners and label tag on the plate insert may still be hot even after the GC oven has cooled down.

  1. Grip the strap on the plate insert and remove it by pulling the bottom edge out first (Figure 6).

  2. 2. Remove the block inserts carefully; do not allow them to contact the column or the MSD source nut.

 

 

島津GC-2010/2014C

島津GC-2010/2014C 進(jìn)樣墊$r$n包含

島津 GCMS-QP2010、

島津 GCMS-QP2010、QP2010S 常用

島津 GCMS-QP5050、

島津 GCMS-QP5050、QP5000 直接接

會員登錄

X

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

X
該信息已收藏!
標(biāo)簽:
保存成功

(空格分隔,最多3個,單個標(biāo)簽最多10個字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時間回復(fù)您~

以上信息由企業(yè)自行提供,信息內(nèi)容的真實性、準(zhǔn)確性和合法性由相關(guān)企業(yè)負(fù)責(zé),化工儀器網(wǎng)對此不承擔(dān)任何保證責(zé)任。

溫馨提示:為規(guī)避購買風(fēng)險,建議您在購買產(chǎn)品前務(wù)必確認(rèn)供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。

撥打電話
在線留言