五月婷网站,av先锋丝袜天堂,看全色黄大色大片免费久久怂,中国人免费观看的视频在线,亚洲国产日本,毛片96视频免费观看

蘇州格羅貝爾生物科技有限公司

BUSINESS

當前位置:> 供求商機> 多極管 Multitrode

[供應(yīng)]多極管 Multitrode

貨物所在地:上海上海市

更新時間:2024-12-31 09:45:36

有效期:2024年12月31日 -- 2025年7月2日

已獲點擊:66

聯(lián)系我時,請告知來自 化工儀器網(wǎng)

The Thomas RECORDING Multitrode is a robust, multiuse, multicontact stainless steel electrode with an electrode array consisting of 7 gold contacts.

Description

The Thomas RECORDING Multitrode is a robust, multiuse, multicontact stainless steel electrode with an electrode array consisting of 7 gold contacts. The contact diameter is 40µm with a spacing of 125µm between the contacts.

The Thomas Multitrode is available in two different lengths

Type I Total length = 136mm

Type II Total length = 110mm.

The frontal probe section of the Multitrode Type I has a length of 80mm and an outer diameter of 300µm and the total length of this probe is app. 136mm where the last 50mm have an outer diameter of 500µm. At the top end of the electrode is a printed circuit board with connection cables. The probe connector is a compact multicontact connector, but other connectors are available on request. The probe tip is electrically connected to the electrode connector as an eights electrode contact and has a distance of app. 650-700µm to the first electrode array contact. Detailed technical data are listed in table 1 below.

Technical Data

Table 1: Technical Data of the Thomas RECORDING Multitrodes

Feature

Multitrode Type I

Mutitrode Type II

Total length

136mm

110mm

Frontal probe section length

80mm

99mm

Frontal probe section diameter

300µm

300µm

Top probe section lenght

45mm

 

Top probe section diameter

500µm

 

Electrode reinforcement tube material

Stainless steel

Stainless steel

Number of electrode contacts

8 = 7 (linear array) + 1 (tip contact)

8 = 7 (linear array) + 1 (tip contact)

Electrode array contact diameter

40µm

40µm

Electrode array contact spacing

125µm

125µm

Electrode array total length

app. 750µm

app. 750µm

Distance tip-first array contact

app. 650-700µm

app. 650-700µm

Electrode contact material

Gold

Gold

Connection interface

Printed circuit board (pcb)

Printed circuit board (pcb)

Figure 1: Thomas RECORDING Multitrode Type II

Figure 2: Thomas RECORDING Multitrode Type I

Features

The Thomas RECORDING Multitrode is a durable, multi-use linear probe. 

  • Durable, multi-use, multi-site linear probe
  • Based on strong electrode material we guarantee for a large number of penetrations through the dura
  • 7 + 1 electrode sites embedded in a stainless steel needle
  • 40 µm micron gold contact electrode site diameter, lacquer insulated, fixed in medical-grade epoxy
  • Fixed inter-electrode spacing of 125 µm (other custom made spacings available on request)
  • Probe diameter is 300µm at the front end (see figure 2)
  • Standard multicontact connector (other connectors on request)

會員登錄

×

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

X
該信息已收藏!
標簽:
保存成功

(空格分隔,最多3個,單個標簽最多10個字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時間回復(fù)您~
撥打電話 產(chǎn)品分類
在線留言