目錄:上海鉑勒機電設(shè)備有限公司>>HACH在線水質(zhì)分析儀>>通用控制器>> LXV401.52.00002
The Model sc100 Controller receives data from one or two sensors. Its plug-and-play, mix-and-match operation lets it fit into any facility or workflow. Digital communication with any Hach digital sensor or probe is simple and reliable. sc100 is also available with RS485/MODBUS® Communications (LXV401.52.02002) or RS232/MODBUS® Communications (LXV401.52.01002). For other communication options which may be available, contact Hach Technical Support or your Hach representative.
A built-in data logger collects measurement at user selectable intervals (1 to 15 minutes), together with calibration and verification points, alarm history, and instrument setup changes for up to 6 months. With a two-year warranty, the Hach sc100 Controller is built to last.
there's no complicated wiring or set up procedures with the sc100 controller. Just plug the sensor in and it is ready for use without special ordering or software configuration.
The Hach sc100 Controller receives data from up to two sensors. Use any of Hach's line of digital sensors for pH/ORP, conductivity, dissolved oxygen, or turbidity.
Not only can the sc100 controller be used for up to two sensors, but the sensors need not be the same. Mix and match any combination of parameters.
Communications using RS485/MODBUS® or Profibus DPV1® protocols are available. (Contact your Hach representative for other communication protocols.) Multiple control functions include built-in PID, control contacts, and alarm functions.
Controller, Mounting Hardware, Basic User Manual
Alarm:Punto de alarma baja, banda muerta del punto de alarma baja, punto alto de alarma, banda muerta del punto alto de alarma, retardo de apagado, retardo de encendido.
Certifications:ETL to UL 61010A-1 and CSA C22.2 No. 1010.1
Communication:RS-232 (MODBUS): Configure and retrieve measured data for one analyzer using IBM-compatible PC RS-485 (MODBUS): Advanced communications/networking with PLC or SCADA system directly from analyzer. Profibus DPV1: Advanced communications/networking with PLC or SCADA system directly from analyzer.
Display:Graphic LCD, 128 x 64 pixels with LED backlighting
Enclosure Rating:NEMA 4X/IP65
Length:5.7 in ( 144 mm )
Mounting:Surface, panel, and pipe (horizontal and vertical)
Operating Humidity:0 to 95% relative humidity, non-condensing
Operating Temperature Range:-20 to 60 °C
Outputs:Two analog 4-20 mA, maximum impedance 500 Ohms, optional digital network connection
Power Requirements (Hz):50/60 Hz
Power Requirements (Voltage):100 - 230 V AC
Relays:Three SPDT, user-configurable contacts rated 100 to 230 Vac, 5 Amp resistive maximum
Warranty:2 years
Weight:3.53 lbs. (1.6 kg)