五月婷网站,av先锋丝袜天堂,看全色黄大色大片免费久久怂,中国人免费观看的视频在线,亚洲国产日本,毛片96视频免费观看

您好, 歡迎來到化工儀器網(wǎng)

| 注冊| 產品展廳| 收藏該商鋪

15601682291

products

目錄:上海鉑勒機電設備有限公司>>HACH在線水質分析儀>>在線電極及其他附件>> 5739001

5739001
  • 5739001
參考價 面議
具體成交價以合同協(xié)議為準
參考價 面議
具體成交價以合同協(xié)議為準
  • 品牌
  • 型號
  • 廠商性質 代理商
  • 所在地 上海市
屬性

>

更新時間:2016-11-27 18:10:12瀏覽次數(shù):817評價

聯(lián)系我們時請說明是化工儀器網(wǎng)上看到的信息,謝謝!

同類優(yōu)質產品

更多產品
Filtrax sample filtration system works reliably, even with a high sludge volume index or floating sludge. The unit has low operating costs and there's no need for an expensive, high maintenance submer

Filtrax sample filtration system works reliably, even with a high sludge volume index or floating sludge. The unit has low operating costs and there's no need for an expensive, high maintenance submersible pump. Continuous air cleaning minimizes cleaning required. High permeate quality.

  • Established Technology In Situ and Down the Line
  • Simple to Use and Maintain
  • Operating Principle
  • Hach's Family of Nutrient Analyzers
  • Works reliably, even with a high sludge volume index or floating sludge

Established Technology In Situ and Down the Line

The Hach Filtrax Sample Filtration System is specifically designed for efficient wastewater analysis. Samples are extracted directly from the activated sludge aeration basin or final settling tank and solids are removed in situ. Separate, high-maintenance submersible pumps become unnecessary. Sample delivery lines and analyzers stay clean. Sample extraction automatically alternates between two continuously cleaned filter elements to allow optimum cleaning of the idle filter. Sample pre-treatment and delivery is continuous and efficient even with a high sludge volume index or floating sludge.

Simple to Use and Maintain

A built-in air purge system in the Filtrax system prevents adhesion of solids to the filter membranes and greatly reduces maintenance cost and time. All tubing is compley accessible and easy to replace. Moving parts never come into contact with the sample. Self-diagnostics provide operators with three levels of error messages if components require attention. Operators control all Filtrax system functions with menu-driven software. The instrument display provides continuous readout of current flow rate through each filter module as well as heater status. Two programmable alarm relays are provided: one relay can be used to alert operators to inspect the Filtrax system when flow decreases and a second programmable relay can shut down the unit if flow decreases further.

Operating Principle

All control components are heated and contained in an IP55-rated enclosure, suitable for outdoor installation. The Filtrax system is made of three components. The control unit is internally heated for outdoor installation. Inside are sample pumps, an air compressor for filter membrane cleaning, and the electronic controller. Filters are constantly cleaned by a vigorous stream of air bubbles against the sides of the module. Two small peristaltic pumps alternay draw wastewater samplse through the two filter membranes for optimum cleaning of the idle filter. The filtration module holder is made of stainless steel and is designed for submerged installation. It contains two filter modules each equipped with an ultra-filtration (0.15 µm) filter membrane. Samples are pulled to the control unit from the filtration module holder with a 15-ft. (5-m) heated suction hose. This hose also contains the air compressor tubing. Samples are then delivered directly to the online measuring instrument.

Hach's Family of Nutrient Analyzers

The Hach Filtrax Sample Filtration System is designed to optimize performance of Hach's Amtax sc Ammonia Analyzer or Phosphax sc Phosphate Analyzer. It also complements Hach's NITRATAX plus sc or NITRATAX clear sc Nitrate Analyzer by supplying solids-free sample to its flow through panel. Rely on the Filtrax system to provide properly conditioned sample to Hach's APA 6000 Alkalinity, Ammonia, Monochloramine, and Phosphate Analyzers too.

Works reliably, even with a high sludge volume index or floating sludge

What's in the box

Filtration system, module holder, delivery hose, user manual

Specifications

Ambient Temperature:-4 °F to 104 °F ( -20°C to 40°C)

Certifications:CE, UL, CSA

Depth:Module holder 13.4 in

Height :Module Holder 19.7 in (500 mm)

Outputs:Two programmable potential free contact (115V or 230V, max. 3 A)

Power Requirements (Hz):50 - 60 Hz

Power Requirements (Voltage):115/220 V AC

Sample Delivery Hose Options:2 m (unheated)

Sample Delivery Hose Options 2:10 m (heated)

Sample Delivery Hose Options 3:20 m (heated)

Sample Flow Rate:Approx. 900 mL/h

Sample Suction Hose:5 m (heated)

Sample Temperature:41 °F to 104 °F (5°C to 40°C)

Weight:Up to 97 lbs. (44 kg) depending on delivery hose option

Width 2:Control unit 3.6 in (92 mm)

- See more at: http://www.hach.com/filtrax-sample-filtration-system-10-m-heated-hose-230-vac/product-details?id=7640095956&callback=qs#sthash.CnF7EM.dpuf- See more at: http://www.hach.com/filtrax-sample-filtration-system-10-m-heated-hose-230-vac/product?id=7640095956&callback=qs#sthash.blFDVY7F.dpuf

會員登錄

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

標簽:
保存成功

(空格分隔,最多3個,單個標簽最多10個字符)

常用:

提示

您的留言已提交成功!我們將在第一時間回復您~
在線留言

會員登錄

請輸入賬號

請輸入密碼

=

請輸驗證碼

收藏該商鋪

該信息已收藏!
標簽:
保存成功

(空格分隔,最多3個,單個標簽最多10個字符)

常用:
熱線電話 在線詢價