寶德角座閥BURKERT氣動調(diào)節(jié)閥主要性能及測試
點擊次數(shù):1218 發(fā)布時間:2013-8-22
寶德角座閥BURKERT氣動調(diào)節(jié)閥主要性能及測試
德國寶帝氣動調(diào)節(jié)閥主要性能及測試: 氣動調(diào)節(jié)閥的性能指標有:基本誤差、回差、死區(qū)、始終點偏差、額定行程偏差、泄漏量、密封性、耐壓強度、外觀、額定流量系數(shù)、固有流量特性、耐振動性能、動作壽命,計13項、前9項為出廠檢驗項目。由于調(diào)節(jié)閥的運輸、工作彈簧范圍的調(diào)整等因素,安裝前往往需要對如下性能進行調(diào)整、檢驗: 1)基本誤差將規(guī)定的輸入信號平穩(wěn)地按增大和減小方向輸入執(zhí)行機構氣室(或定位器),測量各點所對應的行程值,計算出實際“信號-行程”關系與理論關系之間的各點誤差。其zui大值即為基本誤差。試驗點應至少包括信號范圍0、25%、50%、75%、100%這5個點。測量儀表基本誤差限應小于被試閥基本誤差限的1/4。 2)回差試驗程序與上面第1)點所述相同。在同一輸入信號上所測得的正反行程的zui大差值即為回差。 3)始終點偏差方法同第1)點。信號的上限(始點)處的基本誤差即為始點偏差;信號的下限(終點)處的基本誤差為終點偏差。 4)額定行程偏差將額定輸入信號加入氣動執(zhí)行機構氣室(或定位器),使閥桿走*程,實際行程與額定行程之差與額定行程之比即為額定行程偏差。實際行程必須大于額定行程。 5)泄漏量試驗介質(zhì)為10~50℃的清潔氣體(空氣和氮氣)或液體(水或煤油);試驗壓力A程序為:當閥的允許壓差大于350KPa時,試驗壓力均按 350KPa做,小于350KPa時按允許壓差做;B試驗程序按閥的zui大工作壓差做。試驗信號壓力應確保閥處于關閉狀態(tài)。在A試驗程序時,氣開閥執(zhí)行機構信號壓力為零;氣閉閥執(zhí)行機構信號壓力為輸入信號上限值加20KPa;兩位式閥執(zhí)行機構信號壓力應為設計規(guī)定值。在B試驗程序時,執(zhí)行機構的信號壓力應為設計規(guī)定值。試驗介質(zhì)應按規(guī)定流向加入閥內(nèi),閥出口可直接通大氣或連接出口通大氣的低壓頭損失的測量裝置,當確認閥和下游各連接管道*充滿介質(zhì)后方可測取泄漏。產(chǎn)品:袁 :零二一*五三零八六零三九 零二一*五六一八二零六三 一八九一八零七九二七三 一三三零五六六二三六
寶德角座閥BURKERT氣動調(diào)節(jié)閥主要性能及測試
The pneumatic control valve performance and testing: Pneumatic control valve performance indicators are: the basic error, backlash, dead zone, always point deviation, the deviation of rated travel, leakage, sealing, compressive strength, appearance, rated flow coefficient, the inherent flow characteristics and resistance to vibration performance, action life, namely, 13, 9 test items to the factory. Control valve of the transport, the work of the spring range of adjustments, and other factors, before the installation often requires the following capabilities to adjust, test: 1) the basic error of the provisions of the input signal is a smooth increase and decrease direction input actuator air chamber (or locator), the measurement points corresponding to the trip value to calculate the actual "signal - travel relations with the theoretical relationship between the various points of error. And its maximum is the basic error. The test points shall include at least 0,25% of signal range, 50%, 75%, 100% 5 points. Measuring instruments and the basic error limit should be less than 1/4 valves were tested basic error limit. 2) The hysteresis test procedures described in the above 1). The maximum difference measured by the pros and cons of travel on the same input signal is a hysteresis. 3) always point deviation method with 1). The upper limit of the signal (starting point) at the basic error is the starting point bias; the basic error of the minimum signal (end) at the end of deviation. 4) Rated stroke deviation rated input signal to join the pneumatic actuator chamber (or locator), so that the stem end of the route is rated travel deviation, the difference of the actual trip and rated travel and rated travel. The actual itinerary must be greater than the rated travel. 5) leakage test medium for 10 ~ 50 ° C in the clean gas (air and nitrogen) or liquid (water or kerosene); A program of the test pressure: when the valve to allow pressure greater than 350KPa, the test pressure at 350KPa do allowing the pressure to do less than 350KPa; B test procedures differential pressure valve work to do. The test signal pressure should ensure that the valve is turned off. A pilot program, the open air valve actuator signal pressure is zero; gas closing valve actuator signal pressure to the upper limit of the input signal plus 20KPa; two type valve actuator signal pressure should be the design requirements. B test program, the executive body of the signal pressure should be required for the design value. Test medium should be required to flow to join the valve, the valve outlet can direct export of the atmosphere or connected through the atmosphere of low head loss measuring device, when the measurements taken to confirm the valve and downstream of the connecting pipes compley filled with medium before leakage.
寶德角座閥BURKERT氣動調(diào)節(jié)閥主要性能及測試