請(qǐng)輸入產(chǎn)品關(guān)鍵字:
金日立儀器│數(shù)字功率計(jì)│電子負(fù)載│LCR數(shù)字電橋│直流低電阻儀│7116C信號(hào)發(fā)生器│直流電源
上海滬光|線圈圈數(shù)測(cè)量?jī)x-匝間絕緣測(cè)試儀-線圈短路測(cè)試儀
古里KORI SEIKI針盤式帶表卡規(guī)0-10mm/0.05mm│測(cè)厚規(guī)│國(guó)產(chǎn)卡規(guī)│帶表卡鉗表
常州安柏|電橋-低電阻測(cè)試儀-電池內(nèi)阻測(cè)試儀-漏電絕緣電阻測(cè)試儀-負(fù)載
電子計(jì)重秤│計(jì)重臺(tái)秤│地磅│吊鉤秤
電子計(jì)數(shù)秤│計(jì)數(shù)臺(tái)秤│計(jì)價(jià)秤
中國(guó)臺(tái)灣陽(yáng)光sunlilab掃頻儀
國(guó)產(chǎn)-測(cè)溫│測(cè)速│測(cè)光│環(huán)保熱工
國(guó)產(chǎn)-萬(wàn)用表│鉗形電流表│功率表
國(guó)產(chǎn)-信號(hào)源│頻率計(jì)
國(guó)產(chǎn)-儀器儀表檢定裝置數(shù)字高壓表
國(guó)產(chǎn)-電視場(chǎng)強(qiáng)儀│誤碼儀
國(guó)產(chǎn)-電阻箱│電容箱│電感箱│電位差計(jì)│單雙臂電橋
國(guó)產(chǎn)-電參數(shù)│電量測(cè)試儀
國(guó)產(chǎn)-線圈測(cè)量?jī)x│ic測(cè)量
郵編:518033
聯(lián)系人:付先生
電話:0755-83986300/0755-83980158
傳真:0755-83980158
手機(jī):13802268624
留言:發(fā)送留言
個(gè)性化:www.lp-17.com
網(wǎng)址: www.gdojbk.com
商鋪: http://yimoshopping.cn/st118675/
115濕膜梳-115濕膜梳│易高Elcometer│115濕膜測(cè)厚儀
【產(chǎn)品簡(jiǎn)介】
【詳細(xì)說(shuō)明】
如有任何問(wèn)題請(qǐng)與我司業(yè)務(wù)專員:
:豪
:fuhao@17Lp.com
英國(guó)易高Elcometer 115濕膜梳
這些精密不銹鋼濕膜梳可重復(fù)使用,經(jīng)久耐用.
Elcometer 115 濕膜梳有公制或者英制可選,厚度范圍zui高可達(dá)1270μm 或 50mils。精確度為5% 或 2.5μm (0.01mil),取更大者。
每個(gè)濕膜梳有10個(gè)測(cè)量數(shù)值(階齒)
使用濕膜梳
將濕膜梳垂直放置,接觸到基體。保持原地等待幾秒鐘,直到梳齒變濕。拿開濕膜梳.
濕膜厚度在"含漆"或"濕"齒zui大值和"不含漆"或"干"齒zui小值之間
ISO 2808-7B, BS 3900-C5 method 7B, ASTM D4414-A specify that the wet film comb should be perpendicular to the substrate and the thickness of the coating should be stated as lying between the shortest wet tooth and the longest dry tooth.
Wet film combs have teeth of various lengths on their sides.
Place a comb perpendicular to, and touching the substrate. Hold the comb in position and wait a few seconds until the teeth are "wet." Remove the comb from the film.
The wet film thickness lies between the biggest value "coated" or "wet" tooth and the smallest value "uncoated" or "dry" tooth value Example In the diagram, 90 is the biggest value wet tooth and 100 is the smallest value dry tooth. Therefore, the wet film thickness is between 90 and 100 mil/thou. If the volume to solids ratio of the coating is known (if not contact the coating manufacturer) then the wet film thickness can be used to predict the dry film measurement. To use combs on pipes, measure along the longitudinal axis (lengthways) of the pipe. On rough surfaces, measurements will be made from the surface peaks and represent the minimum wet film thickness.
符合以下標(biāo)準(zhǔn) | |
AS/NZS 1580.107.3 | ASTM D 4414-A |
BS 3900-C5-7B | ISO 2808-1A |
ISO 2808-7B | NF T30-125 |
US Navy NSI 009-32 | US Navy PPI 63101-000 |
Elcometer 115濕膜梳
范圍 | 階差 | 部件編號(hào) |
1 - 13mils | 1, 1.5, 2, 3, 4, 5, 7, 9, 11, 13mils | B11529451E |
20 - 325μm | 20, 35, 50, 75, 100, 125, 175, 225, 275, 225, 275, 325μm | B11529455M |
2 - 18mils (51 - 457μm) | 2, 3, 4, 6, 8 10, 12, 14, 16, 18mils (51, 76, 102, 152, 203, 254, 305, 356, 406, 457μm) | B11529452 |
2 - 30mils (51 - 762μm) | 2, 4, 6, 8, 10, 10, 15, 20, 25, 30mils (51, 102, 152, 203, 254, 254, 381, 508, 635, 762μm) | B11529453 |
5 - 50mils (127 - 1270μm) | 5, 10, 15, 20, 25, 30, 35, 40, 45, 50mils (127, 254, 381, 508, 635, 762, 889, 1016, 1143, 1270μm) | B11529454 |
How to use a Wet film Comb - Elcometer Wet Film Measurement